- New Products
- Humidity Temperature
- Calibrator
- Harmonic Clamp Meter
- Digital earth leakag
- Thermometer
- Sound analyzer
- Infrared Thermometer
- Anemometer
- Sound Level Meter
- Lan Cable Tester
- Digital multimeter
- AC/DC Clamp
- Power Supply
- Power Clamp Meter
- Tachomet
- CO2 Tester
- Conductivity meter
- Battery Impedance Te
- PH Meter
- Insulation tester
- Light Meter
- Milli / Micro Ohm Me
- Color Meter
- Heat Stress Monitor
- Flexible Clamp Meter
- EMF Tester
- Luminous Flux Meter
- PV Analyzer
- Luminance Meter
- counter
- LOOP / PSC Tester
- Water quality analyz
- TRMS Power Analyzer
- 3P4W POWER ANALYZER
- Portable Thermal Pri
- Solar Power Meter
- Digital Earth Tester
- Dust meter
- accessories
- Home>
- Products>
- AC/DC Clamp >
- TES-3900/TES-3901 Clamp Meter/Trms Clamp Meter
TES-3900/TES-3901 Clamp Meter/Trms Clamp Meter
- Variable-frequency drives (VFD) V & Hz measurement.
- LoZ voltage measurement to drain ghost voltages.
- Check 3 phase sequence.
- Motor Inrush current measurement.
- True RMS reading on AC and DC+AC mode. (3901)
- uA measurement for HVAC flame sensors. (3901)
- mV measurement range to interface with other accessories. (3901)
- Crest Factor & Harmonic ratio measurement. (3901)
- Data hold, Auto hold & Peak hold mode.
- Max/Min record mode.
- Data memory & read function.
- Variable-frequency drives (VFD) V & Hz measurement.
- LoZ voltage measurement to drain ghost voltages.
- Check 3 phase sequence.
- Motor Inrush current measurement.
- True RMS reading on AC and DC+AC mode. (3901)
- uA measurement for HVAC flame sensors. (3901)
- mV measurement range to interface with other accessories. (3901)
- Crest Factor & Harmonic ratio measurement. (3901)
- Data hold, Auto hold & Peak hold mode.
- Max/Min record mode.
- Data memory & read function.
Model |
3900 |
3901 |
|
AC current |
Range |
99.99A / 999.9A |
99.99A / 999.9A |
Accuracy |
±2%±20dgts (50, 60Hz) ±4%±20dgts (40 to 400Hz) |
±2%±20dgts (50, 60Hz) ±4%±20dgts (40 to 400Hz) |
|
AC voltage |
Range |
999.9V |
999.9mV to 999.9V |
Accuracy |
±1%±20dgts (50, 60Hz) ±2%±20dgts (40 to 400Hz) |
±1%±10dgts (50, 60Hz) ±2%±10dgts (40 to 400Hz) |
|
DC voltage |
Range |
99.99V / 999.9V |
999.9mV to 999.9V |
Accuracy |
±1%±10dgts |
±1%±10dgts |
|
Resistance |
Range |
999.9Ω/99.99KΩ |
999.9Ω to 999.9KΩ |
Accuracy |
±1%±10dgts |
±1%±10dgts |
|
Diode |
Range |
3.000V |
3.000V |
Accuracy |
±1%±10dgt |
±1%±20dgt |
|
Frequency |
Range |
0.5Hz to 400.0Hz |
40Hz to 400.0Hz |
Accuracy |
±0.5%rdg±2dgts |
±0.5%rdg±2dgts |
|
mA (AC+DC) |
Range |
– |
99.99mA/999.9mA |
Accuracy |
– |
±1%±10dgts |
|
Continuity |
≤40Ω±30Ω |
<40Ω |
|
3f Phase sequence indication |
yes |
yes |
|
ACA Inrush current |
yes |
yes |
|
Data hold |
yes |
yes |
|
Auto hold |
yes |
yes |
|
Peak hold |
yes |
yes |
|
Max/Min |
yes |
yes |
|
Memory/Read |
yes |
yes |
|
Accessories |
Instruction Manual, Battery, Carrying case & Test Lead |
||
Size |
HxWxD (mm) |
236x80x39 |
236x80x39 |
Max wire diameter |
30mm |
30mm |
|
Weight |
326g |
326g |
|
Category |
CAT III 1000V , CAT IV 600V |