AFLEX-3003/3005Flexible Power Quality Tester-泰纳电子科技有限公司 



				Flexible Power Quality Tester
AFLEX-3003/3005

Flexible Power Quality Tester

Product Features
  • Power Analysis (3005)
  • W, KW, H.P.
  • VA ,KVA, VAR, KVAR
  • PF, Phase Angle( Φ )
  • Energy (WH, KWH)
  • Dual displays (W+PF, VA+KVAR)
  • Balanced 3 Φ Power Quality and Sequence 

    Harmonics Analysis
  • True RMS (V and A)
  • 3000 A
  • Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
  • Analysis of % THD-F and C.F.
  • Fast Peak Function (33μs and 39μs)
  • Programmable PT (1 to 250 )ratios
  • Auto - Power - Off : 30 Minutes 


    Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm 
Flexible Power Quality Tester introduction
  • Power Analysis (3005)
  • W, KW, H.P.
  • VA ,KVA, VAR, KVAR
  • PF, Phase Angle( Φ )
  • Energy (WH, KWH)
  • Dual displays (W+PF, VA+KVAR)
  • Balanced 3 Φ Power Quality and Sequence 

    Harmonics Analysis
  • True RMS (V and A)
  • 3000 A
  • Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
  • Analysis of % THD-F and C.F.
  • Fast Peak Function (33μs and 39μs)
  • Programmable PT (1 to 250 )ratios
  • Auto - Power - Off : 30 Minutes 


    Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm 

AC Watt (50 or 65 Hz, PF 0.5 to 1, CT=1) AFLEX-3005 only

Range
Resolution
Accuray of reading
100.0 - 999.9 W
0.1 W
2% of range
1.000 - 9.999 KW
0.001 KW
2% of range
10.00 - 99.99 KW
0.01 KW
2% of range
100.0 - 999.9 KW
0.1 KW
2% of range
1000 - 9999 KW
1 KW
2% of range

AC Voltage(50 or 65 Hz, ,Auto Range, True RMS)

Range
Resolution
Accuracy of reading
4.0 V - 600 V
0.1 V
±0.5% ± 5dgts

Harmonics of AC Current in % and Magnitude(1 to 50th order)

Range
Resolution
Accuracy in %
Accuracy of Magnitude
1-20th
0.1%
±2%
±2% of reading ±0.4A
21st-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.4V

AC Current(50 or 65 Hz ,Auto Range, True RMS)

Range
Resolution
Accuracy of reading
0 - 300.0 A
0.1 A
1% of range
300.0 - 999.9 A
0.1 A
1% of range
1000 - 3000 A
1 A
1% of range

Harmonics of AC Voltage in % and Magnitude(1 to 50th order)

Range
Resolution
Accuracy in %
Accuracy of Magnitude
1-20th
0.1%
±2%
±2% ±0.5V
21st-50th
0.1%
±4% of reading ±2.0%
±4% of reading ± 0.5V

Total Harmonics Distortion(%THD-F,1 to 50th order)

Range
Resolution
Accuracy of reading
0.0-20%
0.1%
±2%
20-100%
0.1%
±6% of reading ±1%
100-999.9%
0.1%
±10% of reading ±1%