TES-1604(RS-232)AUTORANGING INSULATION TESTER-泰纳电子科技有限公司 



				AUTORANGING INSULATION TESTER
TES-1604(RS-232)

AUTORANGING INSULATION TESTER

Product Features
  • Innovational logging feature (7000) to memorize all of measurements from the work place
  • RS-232 interface with valued software
  • 4,000M W /V Reding/10,000M W analog indication
  • Backlight illumination
  • 3-3/4 Digital LCD, 4000Count
  • Auto Range for Mega Ohm range
  • 50 segments Log Scaled Analog Display
  • Easy to carry testing package
  • Tests insulation at rated voltage into a 1mA load
  • 200mA short circuit continuity current
  • Meet VED0413
  • Auto discharge 

    CAT II pollution 2 1000V 
    CAT III pollution 2 600V
AUTORANGING INSULATION TESTER introduction
  • Innovational logging feature (7000) to memorize all of measurements from the work place
  • RS-232 interface with valued software
  • 4,000M W /V Reding/10,000M W analog indication
  • Backlight illumination
  • 3-3/4 Digital LCD, 4000Count
  • Auto Range for Mega Ohm range
  • 50 segments Log Scaled Analog Display
  • Easy to carry testing package
  • Tests insulation at rated voltage into a 1mA load
  • 200mA short circuit continuity current
  • Meet VED0413
  • Auto discharge 

    CAT II pollution 2 1000V 
    CAT III pollution 2 600V
AC Voltage
Range
Resolution
Accuracy
600V ACV
0.1Volt
1.5%rdg+3dgt (1V~600V)
Continuity
Range
Resolution
Accuracy
40 Ohm (Ish>200mA )
0.01 W
1%rdg+30dgt
Mega Ohm
Range
Resolution
Accuracy
4000M W /250V w/ autorange 4000M/400M/40M/4M 
4000M W /500V w/ autorange 4000M/400M/40M/4M 
4000M W /1000V w/ autorange 4000M/400M/40M/4M
4000M W /250V, 1count/1K W 
4000M W /500V, 1count/1K W 
4000M W /1000V, 1count/1K W

3%rdg+5Count 
(under 1G W ) 
5%rdg+3Count 
(under 4G W )

GENERAL SPECIFICATIONS
Display 80 x 50mm Big LCD penal with 50 segments analog 
display Max Reading 4000
Over range Indication "OL" will be shown on the LCD penal when out of 
range measurement is made.
Low Battery Indication The  will be shown when the battery need to be changed
Sampling Rate 2.5 times/sec Digital Display 
10 times/sec Bar Graph
Power Source Eight 1.5Volt AA size Battery
Operating Temperature and Humidity 0 ℃ to 40 ℃ (32 ℉ to 104 ℉ ), below 80% RH
Storage Temperature -10 ℃ to 60 ℃ ( 14 ℉ to 140 ℉ )
Dimension 200(L)x140(W)x95(H)mm
Weight Approx. 900g (with battery)
Accessories Test Lead, Battery, Instruction Manual, RS-232 interface, 
Software for Windows .