TES-3079KPower Clamp Meter-泰纳电子科技有限公司 



				Power Clamp Meter
TES-3079K

Power Clamp Meter

Product Features
  • HVAC Application:
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources.
  • Analyze temperature and voltage or current data with the aid of the time stamp.
  • Insulation test up to 100M Ω. 



    Electrical Application:
  • Check for energized circuits and balance loads.
  • 1 Φ /3 Φ (3P3W/3P4W)Power analyzer.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values. 
Power Clamp Meter introduction
  • HVAC Application:
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources.
  • Analyze temperature and voltage or current data with the aid of the time stamp.
  • Insulation test up to 100M Ω. 



    Electrical Application:
  • Check for energized circuits and balance loads.
  • 1 Φ /3 Φ (3P3W/3P4W)Power analyzer.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values. 

ELECTRICAL SPECIFICATIONS (23℃±5)

AC  Current (50Hz to 400Hz) : Trms

Range

Resolution

Accuracy

Sensitivity

Overload Protection

99.99A

   10mA

±2% ±20dgts (50, 60Hz)

±4% ±20dgts (40~400Hz)

0.10A

1000A

999.9A

  100mA

1.0A

 mA Trms : (AC+DC) (Burden Voltage : 5mV/µA) 

Range

Resolution

Accuracy

Sensitivity

Overload Protection

99.99mA

   10nA

±1% ±20dgts

0.20µA

600V

999.9mA

  100nA

2.0µA

 AC  Voltage (50Hz to 400Hz) : Trms 

Range

Resolution

Accuracy

Sensitivity

Overload Protection

999.9mV

0.1mV

±1% ±20dgts (50, 60Hz)

±2% ±20dgts (40~400Hz)

2.0mV

600V

9.999V

1mV

0.020V

99.99V

10mV

0.20V

600.0V

  100mV

2V

 DC  Voltage  

Range

Resolution

Accuracy

Sensitivity

Overload Protection

999.9mV

0.1mV

±1.0% ±20dgts

2.0mV

600V

9.999V

1mV

0.020V

99.99V

10mV

0.20V

600.0V

  100mV

2V

 Resistance (Continuity<40Ω on the 999.9Ω range) : 

Range

Resolution

Accuracy

Overload Protection

999.9Ω

100mΩ

1% ±10dgts

600V

9.999KΩ

99.99KΩ

10Ω

999.9KΩ

100Ω

 MΩ: 

Range

Resolution

Accuracy

Overload Protection

9.999MΩ

1KΩ

5% ±10dgts

600V

99.99MΩ

10KΩ

 Capacitance : 

Range

Resolution

Accuracy

Overload Protection

10.000mF

1nF

1.5% ±5dgts

600V

100.00mF

10nF

1000.0mF

100nF

7000mF

1mF

2.5% ±15dgts

 Diode (Continuity<40mV) : 

Range

Resolution

Accuracy

Overload Protection

2.000V

1mV

±2% ±1dgt

600V

 Temperature (K-Type ther mocouple) : 

Range

Resolution

Accuracy

Overload Protection

-50℃ to 900℃

0.1℃

1% ±1℃

30VAC or 60VDC

-58℉ to 1000℉

0.1℉

1% ±2℉

 1f/3f TRUE Power (KW): (PF>0.5 or θ<60º ) 

Range

Resolution

Accuracy

Overload Protection

60.00KW (<100A)

10W

±5%rdg ±20dgts

(50, 60Hz)

600V ac / 1000A ac

600.0KW (>100A)

100W

 1f/3f Horse Power (HP): (PF>0.5 or θ<60º ) 

Range

Resolution

Accuracy

Overload Protection

80.00HP (<100A)

0.01HP

±5%rdg ±20dgts

(50, 60Hz)

600V ac / 1000A ac

800.0HP (>100A)

0.1HP

 1ψ/3ψApparent Power : 

Range

Resolution

Accuracy

Overload Protection

60.00KVA (<100A)

10VA

±2.5%rdg ±20dgts

600VAC/

1000AAC

600.0KVA (>100A)

100VA

 1ψ/3ψPhase Angle : (50Hz, 60Hz) 

Range

Resolution

Accuracy

Sensitivity

-60° ~ 0° ~ +60°

0.1º

±6.0º

ACV>100V, ACA>10A

 Frequency :                                                                                                          

Range

Resolution

Accuracy

Sensitivity

40Hz/1KHz

0.1Hz

±0.5%rdg ±2dgts

ACV>1.2V, ACA>6A

 

 

 1ψ/3ψPower Factor (PF)

Range

Resolution

Calculated value

Sensitivity

0 ~ +1

0.001

PF=COSθ

ACV>100V, ACA>10A